-40%

Portable 10V Volt DC Precision Reference Voltage Standard 10.0000v Dual powered

$ 47.52

Availability: 16 in stock
  • Restocking Fee: No
  • All returns accepted: Returns Accepted
  • Item must be returned within: 14 Days
  • Return shipping will be paid by: Buyer
  • Brand: Unbranded
  • Condition: New
  • Refund will be given as: Money back or replacement (buyer's choice)
  • Country/Region of Manufacture: United States
  • MPN: Does Not Apply

    Description

    This device can be used to check the calibration of your DVM or DMM.  The output is 10.0000V and conservatively rated to be accurate within 0.0005% (+/- 50uV) when new and within +/-100uV for a minimum of 6 months at room temperature between 68
    º
    F to 86
    º
    F. (20
    º
    C to 30
    º
    C) Initial value was nulled (+/- 10uV) to a calibrated Fluke 332B voltage standard and verified by a calibrated Agilent Keysight 34461A.
    This Fluke 332b voltage standard was nulled to Fluke 5520A calibrator and verified by a Fluke 8508A (+6uV) in local ISO/IEC 17025:2017 accredited electronics calibration shop.
    In order to reach the designed accuracy, thermal equilibrium of the internal electronics is required. Please turn the device on in a constant temperature environment at least 2 hours before taking any measurement.
    The circuit is based on the LT1021-10 which uses buried Zener technology which has excellent long term stability.
    Final adjustments were performed in 25
    ºC (77
    ºF)
    incubator
    after 800+ hours of aging in room temperature and/or 156 hours in 125
    ºC aging oven.
    Temperature compensation circuit included,
    The temperature coefficient of this 10V reference has been tested in
    20ºC 25
    ºC
    &
    30ºC chamber and result shows equal or better than +/-1.0ppm/ºC.
    The device can be powered by two inside 9V batteries or external DC power supply from 16V to 19V. A linear power supply is recommended. This device's built-in input power regulator stabilizes output performance when supply voltage is between 16-19V. DO NOT SUPPLY OVER 20V DC . It is not
    necessary
    remove battery when power by an external power supply, It will use which has higher voltage.  But please remove battery when not in use for a long time ( few
    months
    ) to avoid battery leakage damage this device.
    There is a power status LED. LED lit green indicates battery good or sufficient voltage for proper operation. If battery low or the input voltage is too low, the LED will turn red and cut off output voltage when unable to perform within specification.
    This voltage reference standard is designed and assembled in Texas, USA.
    Unlimited recalibration service is free for the first three years after purchase- just mail it back to us with .00 for USPS first class return shipping charge within the USA.
    If there is manufacturing defect or loss of calibration within the first three years. Ship it back to us with return shipping cost of .00 and we will fix it or send you another one free of charge.